Infectious Diseases EASY Line EASY Line Hepatitis E Virus Antibody Test (Strip) Tests per Package: 50
Serum Code: 15021-2 Package Format: Strip (3mm)
image not exist
  • Stock:
  • Available
    *Usually shipping within 5 business days
  • Min Order:
  • 5 Kits
  • Shipping:
  • Not Included

For Quantity Orders: Request a Quote

  • Stock:
  • Available
    *Usually shipping within 5 business days
  • Min Order:
  • 5 Kits
  • Shipping:
  • Not Included

For Quantity Orders: Request a Quote

Please pay attention to the revision of the document that must be the same as the revision reported in the box label.
In case of discrepancy please contact our Customer Care e-mail: info@adaltis.net.

* Other document related to the product available at Documentation Centre and it is accessible for Adaltis distributors/partners after registration only.

The EASY Line Hepatitis E Virus Antibody Testis a rapid one step screening test for the qualitative detection of Hepatitis E Virus Antibody (HEV) in human serum. Test results are read visually without any instrument.

For “in vitro” diagnostic use only.

EASY Line Hepatitis E Virus Antibody Test is a lateral flow chromatographic immunoassay for the qualitative detection of HEV in serum at the following cut-off concentrations:

Test

Calibrator

Cut-off

Hepatitis E virus (HEV)

Hepatitis E virus

S3

This assay provides only a preliminary qualitative test result. Use a more specific alternate quantitative analytical method to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Apply clinical and professional judgment to HEV test result, particularly when preliminary positive results are obtained.

In acute infection period, anti-HEV IgM is present of high level in the patient’s sera. The IgM antibody titre is decreased significantly and even disappeared in convalescence period, instead IgG is present. Since cases of hepatitis E are not clinically distinguishable from other types of acute viral hepatitis, a correct diagnosis can be made by blood tests which detect the specific anti-viral antibodies.

HBV has a very defined tropism for the liver. Its small genome also necessitates economy, as illustrated by the pattern of its transcription and translation. In addition, HBV replicates through an RNA intermediate and produces and release antigenic decoy particles.

Purified recombinant antigens of HEV are pre-coated onto membrane as a capture reagent on the test band region.

If the Anti-HEV IgM is present in the sample and concentration above the cut-off labeled anti-human IgM-dye complex will be formed. This complex is then captured by antigens immobilized in the Test Zone of the membrane, producing a visible pink colour band on the membrane. The colour intensity will depend on the concentration of the anti-HEV IgM present in the sample. This one step test is very sensitive and only takes about 15-20 minutes. Test results are read visually without any instrument.

The kit contains reagents for 50 tests in strip (code 15021-2).

Individually packed test devices (strip)

50

Number of tests

50

Code

15021-2

The test contains a membrane strip coated with Anti-human IgM μ chain antibody on the test line, a goat polyclonal antibody against gold-protein conjugate at the control line, and a dye pad which contains colloidal gold particles coated with mouse monoclonal antigen specific to HEV.

  • Specimen collection container (for strip, cassette)

  • Disposable gloves

  • Timer

Accuracy

A side-by-side comparison was conducted using EASY Line Hepatitis E Virus Antibody Test and other commercially available rapid HEV Test. Testing was performed on 120 samples. All the presumptive positive and negative results were confirmed by GC/MS. The following compounds were quantified by GC/MS and contributed to the total amount of HEV found in presumptive positive samples tested.

Test

Compounds Contributed to the Totals of GC/MS

HEV

Hepatitis E virus

%Agreement with GC/MS

 

HEV

Positive Agreement

95%

Negative Agreement

100%

Total Results

97.5%

%Agreement with commercial kit

 

HEV

Positive Agreement

99%

Negative Agreement

100%

Total Results

99%

Forty (40) clinical samples for HEV were run using each strip contained within EASY Line Hepatitis E Virus Antibody Test by an untrained operator at a Professional Point of Care site. Based on GC/MS data, the untrained operator obtained statistically similar Positive Agreement, Negative Agreement and Overall Agreement rates as trained laboratory personnel.

*Note: TCA was based on HPLC data.

Reproducibility

Reproducibility studies were carried out using commercially available standards. Each standard was diluted in normal, HEV-free serum to give the appropriate concentration. Each specimen, at each concentration of analyte, was tested four times daily, in duplicate, for five consecutive days. A total of 40 determinations were made at each concentration. The results are given below:

HEV conc.(ng/mL)

Total number of Determinations

Result

Precision

No HEV present

40

40 negative

>99%

S1

40

40 positive

>99%

S2

40

40 positive

>99%

S3

40

40 negative

>99%

Analytical Sensitivity

The results are summarized below.

                 Results of HEV rapid test strip sensitivity

Number

1

2

3

4

5

Concentration

(ng.mL-1)

N1-N20

P1-P12

S1

S2

S3

Test results

-

+

+

+

-/+

Cross-Reactivity

A study was conducted to determine the cross-reactivity of the test with compounds in either HEV-free serum or HEV positive serum. The following compounds show no cross-reactivity when tested with EASY Line Hepatitis E Virus Antibody at concentrations.

Non Cross-Reacting Compound

Specificity of HEV rapid test strip

Analyte

Concentration

Lot 1

Result

Lot 2

Result

Lot 3

Result

Rheumatoid Factor

≤ 100 U/mL

-

-

-

hemoglobin

≤ 875 mg/dL

-

-

-

total bilirubin

≤ 169.8 μmol/L

-

-

-

triglycerides

≤ 6.0 mmol/L

-

-

-

Note: - negative result, + positive result.