top of page
Molecular Diagnostics Adaltis.png

MOLgen real-time PCR

Real-time PCR kits for infectious diseases and genetics

Molecular diagnostic panels and reagent kits for nucleic acid extraction and real-time PCR. MOLgen kits detect, confirm and genotype infectious and genetic diseases by real-time PCR, and cover nucleic acid extraction and PCR set-up, with standardised, simple and reproducible procedures. The lyophilised, ready-to-use master mix ships at room temperature.

Two formats for different cyclers

Each kit code shows its format.
Add 50 µL of extracted nucleic acid to each tube and run.

STR · Strip format

8-tube strips

for microplate cyclers

​

Strips of eight 0.2 mL high-profile tubes moulded together, with dry master mix. Each kit has 6 strips of 8 tubes. Run up to 12 strips of different kits at the same time.

​

Recommended for: AMPLIlab (Adaltis), CFX96™, iCycler iQ5™ and iCycler iQ™ (Bio-Rad), DT-96 and DT-Lite (DNA-Technology), and equivalent instruments.

UNI · Universal format

Single tubes for rotor

and microplate cyclers

​

Individual 0.2 mL high-profile tubes. 48 tubes are sealed under one film; cut off as many as you need.

​

Works with: everything listed for STR, plus Rotor-Gene® Q (Qiagen) and Rotor-Gene® 6000/3000 (Corbett Research).

Why labs choose MOLgen

One workflow from sample to result, with the same protocol across a wide range of targets.
  • Simple workflow covering sample preparation, real-time PCR amplification and result evaluation.

  • Nucleic acid extraction with magnetic particle technology.

  • Lyophilised, ready-to-use master mix for DNA and RNA detection.

  • Unified protocols across single and multiplex targets.

  • Process control at every step, from sample to result.

  • Store kits at 2–8 °C for up to one year. No freezing needed.*

  • Ship kits at up to +25 °C for up to 10 days.*

  • Strip and universal formats for microplate and rotor cyclers.

​​

* Exceptions may apply. See the IFU of each kit.

Nucleic acid extraction & controls

Magnetic-particle extraction kits for manual use and MDXlab cartridges, sample solutions, an internal control and a human-DNA sample validation kit.

Filter by Regulatory Status

Number of products:

10

MOLgen Sample Validation S1

Quantitative detection of human DNA in clinical specimens by real-time PCR.

Code

Format

Pack

081311C

Microplate

96 tests

081312C

Microplate

192 tests

081315C

Microplate

480 tests


MOLgen Universal Extraction

Extraction of DNA and RNA from clinical specimens with magnetic particles.

Code

Format

Pack

081311C

Microplate

96 tests

081312C

Microplate

192 tests

081315C

Microplate

480 tests


MOLgen UniBloodMag (whole blood)

Extraction of nucleic acids from whole blood with magnetic particles.

Code

Format

Pack

081311C

Microplate

96 tests

081312C

Microplate

192 tests

081315C

Microplate

480 tests


MOLgen Universal Extraction (MDXlab)

Universal Extraction in pre-filled cartridges for the MDXlab system.

Code

Format

Pack

081311C

Microplate

96 tests

081312C

Microplate

192 tests

081315C

Microplate

480 tests


MOLgen UniBloodMag (MDXlab)

UniBloodMag whole-blood extraction in pre-filled cartridges for the MDXlab system.

Code

Format

Pack

081311C

Microplate

96 tests

081312C

Microplate

192 tests

081315C

Microplate

480 tests


MOLgen Lysis Solution (M)

Lysis solution for sample pre-treatment.

Code

Format

Pack

081311C

Microplate

96 tests

081312C

Microplate

192 tests

081315C

Microplate

480 tests


MOLgen Transportation Solution 1

Solution for transporting and storing samples.

Code

Format

Pack

081311C

Microplate

96 tests

081312C

Microplate

192 tests

081315C

Microplate

480 tests


MOLgen Transportation Solution 2

Solution for transporting and storing samples.

Code

Format

Pack

081311C

Microplate

96 tests

081312C

Microplate

192 tests

081315C

Microplate

480 tests


MOLgen Hemolytic Solution

Haemolytic solution for blood sample pre-treatment.

Code

Format

Pack

081311C

Microplate

96 tests

081312C

Microplate

192 tests

081315C

Microplate

480 tests


MOLgen Internal Control Sample

Internal control sample to monitor extraction and amplification.

Code

Format

Pack

081311C

Microplate

96 tests

081312C

Microplate

192 tests

081315C

Microplate

480 tests


bottom of page